10 - 2 VOLUME ADJUSTMENT/REPLACEMENT
In case the operability of the right and left levers are poor, and the performed CALIBRA-
TION in test mode does not improve the situation, the cause may be failure of the Volume
Gear’s engagement in the ASSY LEVER MECHA inside the control panel and or Volume
malfunctioning. Follow the following procedure to perform Volume adjustment or re-
placement. Since work is performed inside the energized cabinet, be very careful not to
touch undesigned places.
ADJUSTMENT
Turn power off and remove the CONTROL
PANEL COVER (10-1)
Loosen the 2 cscrews securing the VR
BRACKET in the ASSY LEVER MECHA
to push the gear out of mesh.
With the Lever being at the centering
position, bring the gear into mesh so that
the status of the volume’s shaft is as shown
in (FIG.10.2).
4
5
6
7
8
Fasten the screws securing the VR BRACKET.
Turn power on and perform volume setting in the CALIBRATION in the test mode. (9-3)
During the I/O TEST in the test mode, check to see if the volume value varies smoothly in
accordance with operation of the Lever. (9-3)
Turn off power.
Install the CONTROL PANEL COVER to change back to former state.
2
3
1
VR BRACKET
“D” CUT FACE