Sharp PG-D100U Projector User Manual


 
E-30
Air Filter Maintenance
The air filter should be cleaned every 100 hours of use. Clean the filter more often when the projector is used in a
dusty or smoky location.
Have your nearest Authorized Sharp Industrial LCD Products Dealer or Service Center replace the filter (PFILD
0051CEZZ) when it is no longer possible to clean it.
Cleaning and Replacing the Filter
1 3
Turn OFF
the MAIN POWER.
2
Remove
the FILTER COVER.
Remove
the AIR FILTER.
4 6
Clean the AIR FILTER.
5
Replace the AIR FILTER.
Replace
the FILTER COVER.
AIR FILTER cover
POWER indicator goes off.
Unplug the power cord.
Press
Tab
Open
ONOFF
Place the filter underneath the
tabs on the filter frame.
Return the air filter to its original
position in the filter cover.
Insert the two tabs on the end
of the filter cover into the filter
cover opening and press the
filter cover into position.
Clean the dust off the air filter
and cover with a vacuum
cleaner.
Grasp the air filter between
your fingers and lift it out of
the filter cover.
Press the arrow mark on
the air filter cover and pull
straight out.
Note:
Be sure the AIR FILTER COVER is securely installed. The power cannot be turned on unless it is correctly
installed.