Sharp PG-D100U Projector User Manual


 
E-35
1. PC control
The personal computer can control the projector by connecting the two via an RS-232C cable (not supplied).
2. Communication conditions
Set the serial port settings of the computer to match that of the table below.
Signal format: Conforms to RS-232C standard.
Baud rate: 9600bps
Data length: 8 bits
Parity bit: NON
Stop bit: 1 bit
Flow control: None
3. Basic format
Commands from the computer are sent in the following order: command, parameter, and return code. After the
unit processes the command from the computer, it sends a response code to the computer.
RS-232C Terminal Specifications
Command format
Return code (0DH)C1 C2 C3 C4 P1 P2 P3 P4
Response code format
Normal response
O K
Return code (0DH)
Problem response (communication error or incorrect command)
E R R
Return code (0DH)
Command 4-digits Parameter 4-digits
When more than one code is being sent, send each command only after the OK response code for the previous
command from the unit is verified.
Note:
Using the computer control function of the unit, the liquid crystal projector conditions cannot be read to the computer.
Therefore, confirm the conditions by transmitting the display commands for each adjustment menu and checking the
conditions at the On-Screen Display. If the unit receives a command other than a menu display command, it will execute the
command without displaying the On-Screen Display.
4. Commands
METILORTNOC
DNAMMOCRETEMARAP
STNETNOCLORTNOC
1C2C3C4C1P2P3P4P
GNIHCTIWSTUPNI
IVED___1 1OEDIV
IRGB___1 1BGR
EGAUGNAL
NOITCELES
MELA___1 HSILGNE
___2 HCSTUED
___3 LONAPSE
___4 SDNALREDEN
___5 AKSNEVS
___6 ONAILATI
___7 SIACNARF
___8 ESENAPAJ
OEDIV
METSYS
NOITCELES
MESY___1 OTUA
___2 LAP
___3 MACES
___4 CSTN
OEDIV
EGAMI
TNEMTSUJDA
VAPI_*** )03+~03-(ERUTCIP
VABR_*** )03+~03-(THGIRB
VACO_*** )03+~03-(ROLOC
VATI_*** )03+~03-(TNIT
VASH___* )3~0(SSENPRAHS
VARE___0 OEDIV
___1 TESER
Note:
If a dash appears in the param-
eter column enter a space. If an
asterisk appears enter a value in
the range indicated in brackets
under CONTROL CONTENTS.
See the example on the next
page.