sample output:
Port Q-Size Type Attributes
*S1 0 serial 115200 N 8 1 XON/XOFF RS232
SET PORT
Sets Parameters for specified port. The available commands are dependent on the port type.
CLEAR PORT S1 JOB
This command aborts the currently active job on the port specified. If the remote host is still connected, any further
data received will be discarded.
CL PORT S1 JOB
SET PORT S1 FLOW
Set serial port flow control to NONE, XON/XOFF, CTS, or DSR
SET PORT S1 FLOW <flow>
(default = None)
SET PORT S1 PARITY
Set serial port parity to NONE, EVEN, ODD, MARK, or SPACE
SET PORT S1 Parity <parity>
(Default = None)
SET PORT S1 SIZE
Sets the data bits on the serial port
SET PORT S1 Signal [7 | 8]
(default = 8)
SET PORT S1 SPeed
Sets serial port baud rate. Options for BAUD are 300, 600, 1200, 2400, 7200, 9600, 19200, 38400, 57600, 115200,
230400, and 460800
SET PORT S1 SPEED <baudrate>
(default = 115200)
SET PORT S1 STOP
Sets serial port stop bits per character.
SET PORT S1 STOP [1 | 2]