Sony MKS-2015 Switch User Manual


 
178 Other Settings
Chapter 9 System Settings
a) 1.5 M/E panel only
To test fire the trigger output
Select the output port, and press [Test Fire].
Note
When the selected output port trigger type is [Status], no
trigger is output.
Setting control panel GPI inputs
1
From the top menu, select Setup/Diag >GPI >Panel
GPI In.
The Panel GPI Input menu appears. The status area
shows the GPI input ports, and the trigger type and
action set for the signal to be input to each port.
2
Select the port for which you want to make the setting.
Press directry on the list in the status area.
Use the arrow buttons to scroll the reverse video
cursor.
Turn the knob.
To change the trigger type setting
Press [Trigger Type], to display a popup window, and
select the trigger type.
(falling edge): Trigger is applied on the falling edge
of an input pulse.
(rising edge): Trigger is applied on the rising edge
of an input pulse.
(both edges): Trigger is applied on both falling and
rising edges of an input pulse.
Level: Trigger is applied when input is low level or high
level.
Disable (disabled): Input pulses are ignored.
To change the action setting
When the trigger type is other than [Level] and [Disable],
press [Action] to display a popup window, then you can
select the following actions.
Note
If you change the trigger type setting from any of falling
edge, rising edge, and both edges to [Level], or vice versa,
the action is automatically changed to [No Action].
For details of the action when the trigger type is set to
[Level], see the next item, “Setting the action when the
trigger type is [Level].”
P/P Cut
a)
P/P Cut
M/E Key1 Auto Trans M/E K1 AT
M/E Key1 Cut M/E K1 Cut
M/E Key2 Auto Trans M/E K2 AT
M/E Key2 Cut M/E K2 Cut
DSK1 Auto Trans DSK1 AT
DSK1 Cut DSK1 Cut
DSK2 Auto Trans DSK2 AT
DSK2 Cut DSK2 Cut
FTB Auto Trans FTB AT
FTB Cut FTB Cut
M/E Key1 On M/E K1 On
M/E Key2 On M/E K2 On
DSK1 On DSK1 On
DSK2 On DSK2 On
Error Error
Tally Input1 Tally 1
Tally Input2 Tally 2
Tally Input3 Tally 3
Tally Input4 Tally 4
Tally Input5 Tally 5
Tally Input6 Tally 6
Tally Input7 Tally 7
Tally Input8 Tally 8
Tally Input9 Tally 9
Tally Input10 Tally 10
Tally Input11 Tally 11
Tally Input12 Tally 12
Tally Input13 Tally 13
Tally Input14 Tally 14
Tally Input15 Tally 15
Tally Input16 Tally 16
Tally M/E Tally M/E
No Action No Action
Action button Status area display
Knob Description Setting
values
1 (Port) GPI input port number selection 1 to 8
Action button Status area display
M/E Auto Trans M/E AT
M/E Cut M/E Cut