SSD COMPANY LIMITED 637f Computer Drive User Manual


 
Connector Assignments and Functions 2
________________________________________________________________________________________________________________________________________________________________________________________________________________________
07-02-10-01-E-V0505.doc Product Manaul Type: 637f 27
Signal Connections
Control Signal Plug X10 - SUB D25 Socket
Connection Example
(without option SBT)
model: SUB D 25
control signal plug X10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
drive side
spread out
spread out
PLC
+/- 10V
+24V, I/O-supply
output ready
input active
0V reference point, I/O-supply
24V
+
-
0V
mecanical
limit switches
1)
1)
~
=
L1
N
2)
~
=
L1
N
option: brake
Eurotherm
AC-Servomotor
3 ~
V1
K1
+24V (br)
0V (br)
AC-Servomotor
3 ~
X10.23 X10.9
Brake-Connection Type A :
when Isolation-Type of Break - Installation is
Basic (not PELV). The PELC - Isolation of
Control - Cirquits is uneffected.
Brake-Connection Type B :
when isolation-type of break - installation is
PELV.
PELV-
isolation
2)
V1: Varistor e.g.. Siemens Q69X3431, 38V DC
K1: Couple-relais min. 2A,/60VDC PELV Isolation
Supply may be used for mutliple brakes
option: brake
1) Security- and supervising logic, to be programmed by user !
2) IMPORTANT:
The power-supply for the motor-brake has to be adapted to the type of brake.
Voltage-Drops caused by long cables also may effect malfunctions of the brake.