SSD COMPANY LIMITED 637f Computer Drive User Manual


 
3 Operating Mode
________________________________________________________________________________________________________________________________________________________________________________________________________________________
46 Product Manual Type: 637f 07-02-10-01-E-V0505.doc
3 Operating modes
The preselection of the device functions are carried out by choosing the operating modes 0...5 according to
the following table, see chapter 3.1, (EASYRIDER
®
Windows - Software).
Each operating mode allows the assignment of different in- and output functions (F0..F6).
Operating
mode
Reference-source Hints for selecting the operating
0
1
2
analog (X10.5/18) switchable the operating modes 1 and 2 by input X10.24
speed control analog
torque controller analog
3
analog (X10.5/18) /
digital
simple applications with requirement of switching between
position and speed control position controller (input X10.24)
handling like operating mode 4
4
digital or analog in acc.
to parameter set
general position-controlled systems. Up to 10 positions can be
stored under identifier-numbers and activated like shown.
5 digital or analog in acc.
to programming or via
digital communication
(e.g. fieldbus)
simple to complex systems using instructions BIAS
(up to 1500 command blocks)
PLC - functions
for further information:
see chapter 13.1 and 13.2