INSTALLING THE VTL VALUE APPLIANCE IN AN EQUIPMENT RACK
316196101 • A Chapter 1 Installing VTL Value hardware 5
1. Position the inner rail (A below) against the chassis with the slide-rail lock (B) at the
front.
2. Align the three pairs of keyed openings on the inner rail with the three pairs of locating
pins on the side of the chassis (
C above).
3. While pressing the rear of the rail against the side of the chassis, push the rail toward
the rear of the chassis (
D above) until the rail clip (E) locks into place with an audible
click.
4. Make sure that all six locating pins are locked into the keyed openings.
Next task: Oncebothinnerrailshavebeenattached,goto“Positioningtheouter /middle
railassemblyinthe rack”onpage 5.
Positioning the outer/middle rail assembly in the rack
The VTL Value appliance is four rack-units (4U) high and quite heavy, due to the number of
internal storage disks installed. You must therefore position the appliance in the rack
carefully. The chosen location must allow enough space for a 4U appliance while presenting
the smallest possible tipping hazard. Proceed as follows.