SUPER MICRO Computer 1012G-MTF Server User Manual


 
2-6
A+ SERVER 1012G-MTF USER'S MANUAL
Figure 2-2. Installing the Server into a Rack
(with optional front bezel shown)
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chassis
rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping
the pressure even on both sides (you may have to depress the locking tabs when
inserting). See Figure 2-2.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click".
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the oor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
Warning: Do not pick up the server with the front handles. They are designed
to pull the system from a rack only.
Note: The gure above is for illustrative purposes only. Always install servers to
the bottom of the rack rst.