SUPER MICRO Computer 6014P-TR Network Card User Manual


 
B-14
S
UPERSERVER 6014P-T/6014P-TR User's Manual
Rebuilding Arrays
Note 1: Rebuilding applies to Fault Tolerant arrays (RAID 1) only.
If an array build process (or initialization) is interrupted or critical with one member
missing, you must perform a rebuild to optimized its functionality. For a critical
array rebuild operation, the optimal drive is the source drive.
Note 2: If no spare array exists and a hard disk drive fails, you need to
create a spare before you can rebuild an array.
To Rebuild an array:
1. From the Main Menu, select Manage Arrays. From the list of arrays, select
the array you want to rebuild.
2. Press Ctrl+R to rebuild.
6. Press Enter.
7. Read the warning message as shown on the screen below.
8. Make sure that you have selected the correct disk drives to initialize. If cor-
rect, type Y to continue.