Experimental Audio Equalizer [1..8] Section [1..6] a1: <S: 0, 32>
Sets the a1 coefficient for the given equalizer ID and section number.
The system has 8 user defined equalizers, each made up of 6 second order IIR sections. See the Appendix,
Equalizer section.
Example: Experimental Audio Equalizer 1 Section 1 a1: “0.0”
Experimental Audio Equalizer [1..8] Section [1..6] a2: <S: 0, 32>
Sets the a2 coefficient for the given equalizer ID and section number.
The system has 8 user defined equalizers, each made up of 6 second order IIR sections. See the Appendix,
Equalizer section.
Example: Experimental Audio Equalizer 1 Section 1 a2: “0.0”
Experimental Audio Equalizer [1..8] Section [1..6] b0: <S: 0, 32>
Sets the b0 coefficient for the given equalizer ID and section number.
The system has 8 user defined equalizers, each made up of 6 second order IIR sections. See the Appendix,
Equalizer section.
Example: Experimental Audio Equalizer 1 Section 1 b0: “0.0”
Experimental Audio Equalizer [1..8] Section [1..6] b1: <S: 0, 32>
Sets the b1 coefficient for the given equalizer ID and section number.
The system has 8 user defined equalizers, each made up of 6 second order IIR sections. See the Appendix,
Equalizer section.
Example: Experimental Audio Equalizer 1 Section 1 b1: “0.0”
Experimental Audio Equalizer [1..8] Section [1..6] b2: <S: 0, 32>
Sets the b2 coefficient for the given equalizer ID and section number.
The system has 8 user defined equalizers, each made up of 6 second order IIR sections. See the Appendix,
Equalizer section.
Example: Experimental Audio Equalizer 1 Section 1 b2: “0.0”
Experimental Audio Input Line [1..4] Equalizer ID: <1..8>
Select equalizer ID[1...8].
Example: Experimental Audio Input Line 1 Equalizer ID: 1
Experimental Audio Input Line [1..4] Equalizer Mode: <On/Off>
Determines whether or not the selected equalizer is enabled.
On: Use the selected equalizer
Off: No equalizer
Example: Experimental Audio Input Line 1 Equalizer Mode: Off
Experimental Audio Input Microphone [1..4] Channel: <Left/Right/Mono>
Defines whether the microphone input is a mono signal or part of a multichannel signal.
Left: The microphone input signal is the left channel of a stereo signal.
Right: The microphone input signal is the right channel of a stereo signal.
Mono: The microphone input signal is a mono signal.
Example: Experimental Audio Input Microphone 1 Channel: Mono
Experimental Audio Input Microphone [1..4] EchoControl HighPassFilter: <On/Off>
Set the microphone echo control high pass filter to on/off.
Example: Experimental Audio Input Microphone 1 EchoControl HighPassFilter: On
Experimental Audio Input Microphone [1..4] Equalizer ID: <1..8>
Select equalizer ID[1...8]
Example: Experimental Audio Input Microphone 1 Equalizer ID: 1
Experimental Audio Input Microphone [1..4] Equalizer Mode: <On/Off>
Determines whether or not the selected equalizer is enabled.
On: Use the selected equalizer
Off: No equalizer
Example: Experimental Audio Input Microphone 1 Equalizer Mode: Off
Experimental Audio Output Line [1..6] Equalizer ID: <1..8>
Select equalizer ID[1...8]
Example: Experimental Audio Output Line 1 Equalizer ID: 1
The Experimental menu, cont...
The Advanced configurations menu has an option called Experimental. The settings within this menu can
be used ‘as is’ and will not be documented.
NOTE! The Experimenal menu WILL change.
We recommend you visit the TANDBERG web site regularly for updated versions of the manual.
Go to: http://www.tandberg.com/docs
Contents
Introduction
Getting started
About the menus
The Settings menu
The Settings library
Cameras
Appendices
Contact us
The Settings library