8900NET Instruction Manual 25
Using the 8900NET GUI
Figure 13. 8900NET GUI for Frame Control
Module Slot Status
Module Slot Status icons report one of the following (Table 4):
Table 4. Module Status Indicators
Icon
Color
Module
Status
Icon
Text
Indication
White None Empty No module detected in slot.
Gray No Comm No Comm Slot contains a legacy module which was not designed to support Frame
Bus communications with an 8900NET module.
Green Pass Module Slot contains a fully Frame Bus capable module.
Yellow Warning Module 8900NET has detected a warning condition in module due to lack of input
signal or incomplete support for remote monitoring and control. Ability of
module to perform intended operation is limited.
Red Fault Module 8900NET has detected a fault condition in module. Fault may have been
communicated over the Frame Bus, or may indicate a failure of the module
to respond over the Frame Bus.
0612-12r1
The Links section lists the frame and its current modules. The selected link's Status
page is first displayed and the sub-list of links for the selection is opened. The sub-list
allows you to select a particular information page for the selected device.
Content display section displays the information page
for the selected frame or module (frame slot icons are also
active links).
Online Manual Link
Refresh button for manual
refresh of page