34 8900NET Instruction Manual
Using the 8900NET GUI
Media Module Slot Configuration
Media module slots may be named to reflect specific functions for that slot
or module within the facility. The assigned name is stored on the 8900NET
module and travels with that module if it is moved to another frame. To
assign a slot name you must access the specific slot’s page and open the Slot
Config menu for that slot. An example for the 8960DMX is shown in
Figure 20.
Figure 20. Media Module Slot Configuration Page
Locate Module
When enabled, the Locate Module function flashes the yellow COMM and
CONF LEDs on the front of the module to locate in the frame.
Slot Identification
You may identify the module by typing a specific name in the Name field.
The assigned name is stored on the 8900NET module and travels with the
8900NET module if it is moved to another frame. Select
Default to enter the
factory default module name.
Read-only status of 2000NET
module hardware settings
necessary for enabling
SNMP Trap Reports
Enable/disable specific
SNMP reports for the slot
Read-only severity level
assigned to each event
Name the module slot
Identify the input signal
Learn module configuration
to this slot
Check box to restore
saved config when
new module installed
Enable/disable module
locator function
Select Slot Config