Toshiba GD-1270 Fax Machine User Manual


 
GD-1210/1250/1270/1160/1260 © 2006 - 2011 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSIS MODE
2 - 10
Code
Adjust-
ment
Function Setting
Default
ASM AUS HKG USA DEU GBR ITA BEL NDL
13-
108
LCC
allowed
gaps
(PABX)
(Line 1)
Sets the inter-
ruption time for
the PABX to be
ignored during
LCC.
0: OFF
1: 50 ms
2: 100 ms
3: 200 ms
000033333
13-
109
DTC
allowed
gaps
(PABX)
(Line 1)
Sets the inter-
ruption time for
the PABX to be
ignored during
DTC.
0: OFF
1: 320 ms
2: 160 ms
3: 240 ms
111111111
13-
110
DTC/
LCC for
PABX
(Line 1)
Selects which is
to be used for
the PABX, DTC
or LCC.
0: BZT
(DTC/LCC)
1: LCC 5 sec
2: DTC only
3: FRN
(DTC/LCC)
4: DTC (JPN)
5: NO
DTC&LCC
555555555
13-
111
DTC
time out
(PABX)
(Line 1)
Sets how long
the dial tone
detection is per-
formed.
0: 20 sec
1: 10 sec
2: 8 sec
3: 15 sec
4: 3.3 sec
000111111
13-
112
BTC fre-
quency
(Line 1)
Sets the busy
tone frequency
to be detected
for the PSTN
and PABX.
0: Not
detected
1: 300-600 Hz
2: 350-550 Hz
3: 300-500 Hz
4: 300-700 Hz
000111111
13-
116
Dial T1
timer
(Line 1)
Sets the time to
wait for a
response from
the receiver
after dialing is
completed.
0: 60 sec
1: 35 sec
2: 90 sec
3: 55 sec
4: 115 sec
030322222
13-
117
Dial stop
after T1
In case of T1
time-out (no
response from
the receiver)
during the auto-
matic dialing,
redialing is not
performed and
it is determined
that the trans-
mission is ter-
minated due to
error.
0: OFF
1: ON
000100000
13-
122
CML
make
time
before
dialing
Pause before
dialing
0: 0 ms
1: 10 ms
¦
255:2550 ms
222222222
11/10