TROUBLESHOOTING
3 - 13
3
3) Function List for Maintenance
Settings for the Self Diagnosis Mode (13) for the FAX operation are output.
Fig. 3-6
4) Memory dump list (System)
Command/status information between the CPU controlled by the FAX board and the CPU of the
equipment is reported.
5) Memory dump list (FAX)
Command/status information between the CPU controlled by the FAX board and the CPU of the
equipment is reported.
Fig. 3-7
6) Transmission journal
Transmission records for 40 communications are listed. Occurrence conditions of the communica-
tion errors can be checked with information such as the time when the communication took place,
error codes, etc. Error code “50” indicates that the other party’s line of the other side is busy (talk-
ing). If this error occurs frequently, it can be decreased somewhat by increasing the number of redi-
aling attempts. Also, it can be checked if the communication fails with a particular address.
7) Reception journal
Reception records for 40/120 communications are listed. Occurrence conditions of the communica-
tion errors can be checked with the information such as the time when the communication took
place, error codes, etc. Also, it can be checked if the communication fails with a particular address.
CODE NO DATA CODE NO DATA CODE NO DATA CODE NO DATA
116 1 505 1 707 2 909 3
303 15
FUNCTION LIST FOR MAINTENANCE ROM VER
TIME
: MM-DD-YY HH:MM
TEL NO.1
: XXXXXXXXX
TEL NO.2
: XXXXXXXXX
NAME : XXXXXXX
ADDRESSH EX DATA ASCII
0xB0080000 0001020304050607 08090A0B0C0D0E0F
0xB0080010 3031323334353637 38393A3B3C3D3E3F 0123456789ABCDEF
FUNCTION LIST FOR MAINTENANCE ROM VER
TIME
: MM-DD-YY HH:MM
TEL NO.1
: XXXXXXXXX
TEL NO.2
: XXXXXXXXX
NAME : XXXXXXX