SELF-DIAGNOSIS MODE
2 - 32
Code
Adjust-
ment
Function Setting
Default
ASM AUS HKG USA DEU GBR ITA BEL NDL
13-
331
Echo
protec-
tion
delay
(high
speed)
(V.21)
Sets if a delay
(500 ms) is
inserted before
sending the
V.21 signal and
timing is shifted
to avoid the line
echo.
0: OFF
1: ON (500
ms)
101111111
13-
335
Modem
speed
initial
value
Sets the initial
modem speed
to be declared
by DIS/DCS.
0: 2,400 bps
1: 14.4 kbps
(V.17)
4: 4,800 bps
5: 12 kbps
(V.17)
8: 9,600 bps
9: 9,600 bps
(V.17)
12: 7,200 bps
13: 7,200 bps
(V.17)
111111111
13-
338
Forcible
line
monitor-
ing
Selects the line
to monitor.
0: OFF
1: Line 1
2: Line 2
000000000
13-
339
CI-ON
deter-
mine
time
(Line 1)
CI ON-satiable
time.
0: 175 ms
1: 125 ms
2: 800 ms
3: 145 ms
000000000
13-
340
CI-OFF
deter-
mine
time
(Line 1)
CI OFF-satia-
ble time.
0: 650 ms
1: 350 ms
2: 175 ms
3: 90 ms
222222222
13-
346
Record-
ing width
capacity
declara-
tion
Selects either
one of the fol-
lowings to
declare the
maximum
recording width
to the other
party when the
specified paper
size is not avail-
able; the largest
paper in the
other drawer or
the drawer for
the largest
paper.
0: Paper
1: Drawer
000000000
13-
350
High
speed
carrier-
OFF
detec-
tion
timer
Sets the time to
determine the
carrier signal is
stopped com-
pletely.
0: 1.5 sec
1: 6 sec (FTZ)
111111111