SELF-DIAGNOSIS MODE
2 - 44
Code
Adjust-
ment
Function Setting
Default
ASM AUS HKG USA DEU GBR ITA BEL NDL
13-
566
Fall-
back
condi-
tion for
receiver
(No. of
PPR
trans-
mis-
sion)
(V.34
Line 1)
Sets the num-
ber of the PPR
transmission for
fall-back condi-
tion in V.34
reception.
0: Once
1: Twice
¦
10: 11 times
555555555
13-
567
TX
attenua-
tion
value
(V.34)
(Line 1)
Sets the
modem trans-
mission attenu-
ation level for
the V.34 com-
munication. The
smaller the set
value is, the
higher the
transmission
level becomes.
If errors occur
frequently or
training is not
sent, the trans-
mission level
should be
changed.
0: 0 dB
1: -1 dB
¦
15: -15 dB
(Value
decreased one
by one)
10 10 10 10 12 12 12 12 12
13-
569
Initial
modem
speed
for V.34
commu-
nication
Sets the initial
modem speed
for V.34 com-
munication.
0: V.34 not
installed
6: 14.4 kbps
(V.34)
9: 21.6 kbps
(V.34)
12: 28.8 kbps
(V.34)
14: 33.6 kbps
(V.34)
14 14 14 14 14 14 14 14 14
13-
571
SUB/
SEP/
PWD
func-
tions
Sets SUB/SEP/
PWB communi-
cation at data
reception.
0: OFF
1: ON
111111111
13-
574
Coding
capabil-
ity (com-
municati
on capa-
bility)
Sets the coding
capability to be
declared to the
other side dur-
ing communica-
tion.
0: MH
1: MH/MR
2: MH/MR/
MMR
3: MH/MR/
MMR/JBIG
333333333
13-
575
Recep-
tion end
tone tim-
ing
Sets the timing
to sound the
reception end
tone.
0: OFF
1: When print-
ing is com-
pleted
2: When
reception is
completed
111111111
11/10