Xantrex Technology XDC 20-300 Power Supply User Manual


 
SCPI Command Summary
TM-XDOP-01XN C–15
Set High Current
Limit
[[:]SOURce][<channel>]:CURRent:LIMit:HIGH
{<current>|MAXimum|MINimum}
Set upper limit of current setpoint
range (soft limits)
Yes
Set Low Current
Limit
[[:]SOURce][<channel>]:CURRent:LIMit:LOW
{<current>|MAXimum|MINimum}
Set lower limit of current setpoint
range (soft limits)
Yes
Set High Power
Limit
[[:]SOURce][<channel>]:POWer:LIMit:HIGH
{<power>|MAXimum|MINimum}
Set upper limit of power setpoint
range (soft limits)
Yes
Set Low Power
Limit
[[:]SOURce][<channel>]:POWer:LIMit:LOW
{<power>|MAXimum|MINimum}
Set lower limit of power setpoint
range (soft limits)
Yes
Set High Voltage
Limit
[[:]SOURce][<channel>]:VOLTage:LIMit:HIGH
{<voltage>|MAXimum|MINimum}
Set upper limit of voltage setpoint
range (soft limits)
Yes
Set Low Voltage
Limit
[[:]SOURce][<channel>]:VOLTage:LIMit:LOW
{<voltage>|MAXimum|MINimum}
Set lower limit of voltage setpoint
range (soft limits)
Yes
Table C-4
Commands for Current Share
Function SCPI Command Description Query
Set Current Sharing
Mode
[[:]SOURce][<channel>]:COMBine:CSHare:MODE
{NONE|MASTer|SLAVe}
Select current share mode Yes
Read Summed
Current
[:]MEASure[:SCALar]:CURRent[:DC]? SUM
Read total current output of all
current sharing supplies
N/A
Table C-3
Commands for Output Control
Function SCPI Command Description Query
TM-XDOP-01XN.book Page 15 Monday, July 17, 2006 11:19 AM