Xantrex Technology XDC 20-300 Power Supply User Manual


 
SCPI Command Summary
TM-XDOP-01XN C–31
Program specific
sequence step
current
[:]PROGram[<channel>]:SEQuence<sequence_number>
:STEP<step_number>:CURRent <current>
Edit/program step current of
specific sequence
Yes
Program specific
sequence step
voltage
[:]PROGram[<channel>]:SEQuence<sequence_number>
:STEP<step_number>:VOLTage <voltage>
Edit/program step voltage of
specific sequence
Yes
Program specific
sequence step
power
[:]PROGram[<channel>]:SEQuence<sequence_number>
:STEP<step_number>:POWer <power>
Edit/program step power of
specific sequence
Yes
Program specific
step OVP
[:]PROGram[<channel>]:SEQuence<sequence_number>
:STEP <step_number>:OVP <OVP_level>
Edit/program step OVP level of
specific sequence
Yes
Program specific
sequence step time
[:]PROGram[<channel>]:SEQuence<sequence_number>
:STEP <step_number>:DWELl {<step_time>|TRIG}
Edit/program step time or
triggering of specific sequence
Yes
Program specific
sequence trigger
source
[:]PROGram[<channel>]:SEQuence<sequence_number>
:TRIGger:SOURce {BUS|MANual|EXTernal|IMMediate}
Edit/program trigger source of
specific sequence
Yes
Program specific
sequence end action
[:]PROGram[<channel>]:SEQuence<sequence_number>
:REPeat
{<sequence_count>|ONCE|FORever|INFinity}
Edit/program end action of
specific sequence
Yes
Table C-14
Auto Sequence Commands
Function SCPI Command Description Query
TM-XDOP-01XN.book Page 31 Monday, July 17, 2006 11:19 AM