Zebra Technologies 400 Printer User Manual


 
Resetting Printer Parameters
Resetting Factory Defaults
If it is ever necessary to reset all of the factory default values, press and
hold the FEED and PAUSE buttons while turning on the power.
Permanently save these values in memory by pressing the MODE button
four times; the DARKEN, POSITION, and CALIBRATE LEDs will flash,
indicating the changes have been saved. To return to printing mode, turn
off and then turn on the printer.
Resetting Communications Parameters
Pressing and holding the FEED, PAUSE, and MODE buttons while turning
on the power resets only the communications parameters to 9600 baud, 8 bit
word length, no parity, and 1 stop bit. Permanently save these values in
memory by pressing the MODE button four times; the DARKEN,
POSITION, and CALIBRATE LEDs will flash, indicating the changes have
been saved.
Resetting Ribbon Parameters
If it is ever necessary to reset the ribbon parameters to the factory default
values, follow this procedure:
1. Turn off the printer.
2. Open the printhead and remove the ribbon.
3. Turn on the printer while pressing and holding the FEED, CANCEL,
and MODE buttons.
4. After the PRINTHEAD LED flashes, reload the ribbon.
5. Close the printhead.
NOTE: A label automatically prints, showing the ribbon sensor profile.
6. To save, press the MODE button four times.
46 S400 & S600 User’s Guide
54