Zebra Technologies SL5000r/T5000r Printer User Manual


 
27
^B$D - FIM
Command Format:
^B$D
fp, type, height
d: FIM barcode command
fp:
Barcode orientation
N = No Rotation (Default)
R = Rotate 90 degrees, clockwise
I = Rotate 180 degrees, inverted
B = Rotate 90 degrees, counter-clockwise
type:
Type of FIM barcode. Only four choices are valid:
A (default), B, C, and D.
^B$E - German Interleaved 2 of 5
Command Format:
^B$E
fp, hgt, rdt, po
s
e: German Interleaved 2 of 5 barcode command
fp:
Barcode orientation
N = No Rotation (Default)
R = Rotate 90 degrees, clockwise
I = Rotate 180 degrees, inverted
B = Rotate 90 degrees, counter-clockwise
hgt:
Barcode Height
Value entered in dots at the printer dpi.
The default is 10 dots or the height set by the ^BY command.
If the height exceeds the label length, then the barcode is
cut off at the bottom of the label.
rdt:
Human readable data
Y = Print human readable data (Default)
N = No human readable data
pos:
Human readable data print position
Y = Print it above the barcode
N = Print it below the barcode (Default)
^CI - Select International Set
Each character set contains different individual characters. PPI uses scalable
fonts rather than bitmapped fonts.
Table 1. Printer Character Sets by Group
Group Name Character Set Name Character Set ID
Standard Sets USA 1 000
USA 2 001
UK 002
Holland 003
Denmark/Norway 004
Sweden/Finland 005