Zebra Technologies SL5000r/T5000r Printer User Manual


 
33
^JE - Disable Diagnostics
This command disables Hex Dump mode.
~JP - Pause & Cancel
The PPI ONLINE light is illuminated when the printer is online.
^JU - Configuration Update
This command controls whether the printer reprints a label after a fault
condition clears.
^JU
op
,
num
op
= Configuration update operation to perform.
F: Load factory configuration
R: Load saved configuration number
num
S: Save current configuration as power-up configuration
number
num
num
= Configuration number to load, used only when
op
= R or S
^JV - Configuration Update
This command saves/loads the configuration ^JV
a
[,
m
]
a
= F: Load factory emulation
S: Save configuration and as power-up configuration
R: Load saved configuration
m
= 1 ... 8 (config number)
^JZ - Reprint After Error
The current setting is reflected in the corresponding front panel value. The
conditions which generate a fault are determined by, and may be unique to,
PSA.
~Lx - Base Emulation Support
PPI supports text printing using the LP+ emulation.
In addition to the three front panel LP+ Text Mode selections, there are three
PPI commands which allow you to select the LP+ Text Mode through the data
stream:
~L0 - LP+ Text Mode = Absorb (ZPL compatibility)
~L1 - LP+ Text Mode = Auto Pass-thru
~L2 - LP+ Text Mode = ZGL Quiet
With LP+ Text Mode set to “Absorb,” all non-PPI data is absorbed including
any system-generated line terminators.