A SERVICE OF

logo

iTherm
®
280 Programmer’s Guide Programming Codes
28-07764 Rev C Page 211
Bit Off/On Hex Decimal Status for Automatic Status Back (ASB)
0 Off 00H <0> Not used; fixed to Off
1 Off 00H <0> Not used; fixed to Off
2 Off 00H <0> Drawer kick-out connector pin 3 low
On 04H <4> Drawer kick-out connector pin 3 high
3 Off 00H <0> On-line
On 08H <8> Off line
4 On 10H <16> Not used; fixed to On
5 - - - Undefined
6 Off 00H <0> Paper is not being fed by the FEED Button
On 40H <64> Paper is being fed by the FEED Button
7 Off 00H <0> Not used; fixed to Off
Table 29 Automatic Status Back (ASB) First Byte (Printer Information)
Bit Off/On Hex Decimal Status for Automatic Status Back (ASB)
0 - - <0> Undefined
1 - - <0> Undefined
2 Off 00H <0> No mechanical error
On 04H <4> Mechanical error occurred
3 Off 00H <0> No Auto-cutter error
On 08H <8> Auto-cutter error occurred
4 Off 00H <0> Not used; fixed to off
5 Off 00H <0> No unrecoverable error
11
On 20H <32> Unrecoverable error occurred
6 Off 00H <0> No temporary abnormality of the print head
temperature (high temperature)
On 40H <64> Temporary abnormality of the print head
temperature (high temperature) occurred
7 Off 00H <0> Not used; fixed to Off
Table 30 Automatic Status Back (ASB) Second Byte (Error Information)
11
The iTherm® 280 can not recover from mechanical errors without flushing the input buffer. All
print data will be lost if a mechanical error occurs.