![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/ec/5ec8a814-9550-4eef-8f77-98a9fcc45888/5ec8a814-9550-4eef-8f77-98a9fcc45888-bge4.png)
Programming Codes iTherm
®
280 Programmer’s Guide
Page 226 Rev C 28-07764
Hexadecimal 10H 14H <8> d1…d7
Decimal <16> <20> <8> d1…d7
Range d1=1, d2=3, d3=20, d4=1, d5=6, d6=2, d7=8
Description The [DLE] [DC4] <8> command clears all data stored in the receive buffer and
the print buffer.
Transmits the following three bytes of data
Hex Decimal Amount of data
Header 37H 55 1 byte
Flag 25H 37 1 byte
NUL 00H 0 1 byte
Enters in standard mode
Function Select Peripheral Device Status
ASCII [ESC] = <n>
Hexadecimal 1BH 3DH <n>
Decimal <27> <61> <n>
Range 1 ≤ n ≤ 3
Description The [ESC] = <n> command selects the device to which the host computer sends
data, based on the value of <n> listed below.
Bit Off/On Hex Decimal Function
0 Off 00H <0> Printer disabled
On 01H <1> Printer enabled
1 Off 00H <0> Customer display disabled
On 02H <2> Customer display enabled
2-7 - - - Undefined
Table 48 Peripheral Device Bit Definitions
Note: Epson Customer display is not supported by the iTherm
®
280
printer.