A SERVICE OF

logo

4–8
SCANTEAM 3700 Wedge Technical Manual
Reread Delay
This programming selection allows you to set a time period that must pass
before the 3700 Wedge can read the same bar code again. Setting a reread
delay protects against accidentalrereads of the same bar code. Longer delays
are effective in minimizing accidental rereads at POS (point of sale) terminals.
Use shorter delays in applications where repetitive bar code scanning is
required.
Default = Low (175 milliseconds).
Good Read Delay
This programming selection allows you to set a time period that must pass
before the 3700 Wedge can read another bar code. Some terminals require a
slower read rate. By setting a good read delay, you can ensure a good read.
Default = None.
Voting
When this selection is enabled, the 3700 Wedge requires multiple identical,
consecutive decodes before the bar code data will be accepted andtransmitted
to the terminal. Default = Disable.
High (1.0 second)
Extra High (2.0 seconds)
Low (175 milliseconds)
Medium (450 milliseconds)
None
Low (500 milliseconds)
Medium (1.0 second)
High (1.5 second)
Enable
Disable