34
Parameter Description
Default
(BCF...)
Default
(BC...)
min MAX
I.F.R.
B01 Room thermostating temperature in the first phase -48°F -13°F -58°F 122°F
B02 Under surface T control start temperature
41°F 86°F -58°F 210°F
B03 First coefficient of the control relation
0 -2 -50 50
B04 Second coefficient of the control relation
0 16 -50 50
B05 Third coefficient of the control relation
-8 -8 -50 50
B06 Under surface T initial value determining the end of the first phase
30°F 34°F -58°F 210°F
B07 Phase two formula coefficient
99 10 0 99
B09 Under surface t min. value allowed during the third phase
32°F 30°F -58°F 210°F
B10 End of intelligent quick cooling core temperature
46°F 38°F -58°F 210°F
B11
Delay from the positive result of the needle test for starting the
procedure to determine the end of the first phase
60 sec 60 sec 0 sec 99 sec
B12 First phase temperature detection time
30 sec 30 sec 0 sec 99 sec
B13 First phase min. duration
6 min 6 min 0 min 99min
B16 Defrost on starting intell. QC cycle (0=no 1=yes)
0 0 0 1
B17 Inhibition temperature
194°F 176°F -58°F 210°F
B18
Room Set point in the event of automatic switch to time or
temperature mode
19°F 32°F -58°F 210°F
B19 Max. duration possibile for intelligent QC process
999 min 150 min 1 min 999 min
B20
Under surface T safety value determining the end of the first
phase
30°F 38°F -58°F 210°F
B21 First coefficient of the room thermostating curve (third phase)
10 -25 -90 99
B22
Second coefficient of the room thermostating curve (third
phase)
-50 -28 -90 99
B23
Storing activation at the end of intell. QC cycle
(0 = no; 1 = yes)
1 1 0 1
B24 Room thermostat Set-point in storing
36°F 36°F -130°F 194°F
B26 Core temperature limit for the timer start
999 0 0 999
B27 Adjuster of fans speed in the third phase
99 0 0 99
B28 Cold pulse adjuster
10 0 0 99
COMMUNICATION
ADD Device Address 1 1 1 147
SC
Serial Control :
0 = not activated
1 = print
2 = ModBus
1
1
0
2
MB1 BaudRate: 0 = 2400; 1 = 4800; 2 = 9600; 3 = 18200
2 2 0 3
MB2 Parity: 0 = no parity; 1 = odd; 2 = even
2 2 0 2
TYPE OF CYCLE
G01
Positive QC cycles only :
0 = Positive and Negative
1 = Positive only
0 0 0 1
CHANGING PARAMETERS
Press menu/esc to select the desired menu
Use the keys up and down to display
Press enter to confirm your choice.
The display shows
(only the 1st time)
S
ervice
E
sc
S
ervice
Password 0