3Com 3C16020 Power Supply User Manual


 
DUA1602-0AAA01
3-6
C
HAPTER
3: C
ONFIGURING
T
HE
M
ANAGEMENT
M
ODULE
BOOTP retries (BR)
Type
BR
followed by a space and the number of times the
Management Module should request BOOTP configuration. You
can specify any positive number up to 255 (the default is 30). If
you set this field to 0, no BOOTP requests are made. To have the
module request BOOTP configuration repeatedly until it receives a
successful configuration, specify –1 in this field. Retries are sent at
approximately two-minute intervals.
Press [Enter] to save the new setting and return to the
configuration screen.
Be sure to set this field to 0 if your network does not have a
BOOTP server. If you specify any other value, you have to wait
while the Management Module powers on and receives a
successful BOOTP configuration (or completes the specified number
of requests).
Authorized Password (PW)
This field is reserved for future use.
Command Security Level (LV)
To change the command security level, type LV followed by a space
and the corresponding level number. This command determines
who receives data or sends commands.
There are three possible entries:
1
,
2
, or
3
.
1 The standard level allows anyone with the correct community name (for
SNMP) to receive data or send commands. The standard level is the
default.