3Com 3C16020 Power Supply User Manual


 
DUA1602-0AAA01‘
Changing the Configuration Fields 3-9
sysContact (SC)
Type
SC
followed by a space and the “system contact name“ to
change this field. You must use quotes to enclose the system
contact name.
Type up to 63 alphanumeric characters to identify someone to
contact with questions about this device. For example, you can
type a person’s name, phone number, department, or physical
location. (If you do not specify a system contact here, you can do
so using your SNMP management application.)
Press [Enter] to save the new setting and return to the
configuration screen.
sysLocation (SL)
Type
SL
followed by a space and the “system location name“ to
change this field. You must use quotes to enclose the system
location.
Type up to 63 alphanumeric characters to identify the location of
the installed Management Module.
Press [Enter] to save the new setting and return to the
configuration screen.
Attached Devices (AD)
To list the protected equipment currently connected to the UPS,
type
AD
followed by a space and the “device name“. You must
use quotes to enclose the attached devices.
Type up to 63 characters (for device names) to identify other
SuperStack devices, such as hubs and switches, that are connected
to the UPS.
Press [Enter] to save the new setting and return to the
configuration screen.