3Com 7000 Switch User Manual


 
Upgrading from E-IISP to PNNI
83
Method 1 - Shift “O”
1
Reboot the switch
2
Within 3 seconds of rebooting press Shift “O”
3
Perform the menu item
(1) SYS \(3) LOA \ (3) LCL \ 0
The system is now in operational mode.
Method 2 - dbgoff.bat
1
Run the batch file dbgoff.bat:
a
Type dbgoff.bat
b
Type the appropriate ComPort switch (com1/com2)
c
Type the appropriate Speed switch (19200/57600/115200)
d
Press Enter
e
Wait for completion
2
Reboot the switch
The system is now in operational mode.
Upgrading from
E-IISP to PNNI
For full upgrade instructions, see Chapter 6 in the
CoreBuilder 7000
Family ATM Switches Management Guide
.The CoreBuilder 7000 has a
special gateway function which allows E-IISP to PNNI connectivity and
vice versa.
PNNI is available in version 4.5 extended only.
PNNI in E-IISP
Connecting PNNI to E-IISP is done in two ways:
Using the 3.1 interface
Using the PNNI to IISP/E-IISP gateway
Connecting PNNI to E-IISP and IISP networks requires addressing to match
(use the same E.164 addressing scheme) in order to guarantee
uniqueness. This is necessary because PNNI works on the best match
routing scheme. The PNNI gateway function will advertise IISP and/or
E-IISP addresses as either native or as foreign reachability addresses.