3Com RMON-EMP-3 Network Card User Manual


 
Configuring the Module 3 - 41
Warm-Starting the RMON MultiProbe Module
When you re-initialize the RMON MultiProbe Module by initiating a warm
start (for example, by pressing the Reset button), all collected information
stored in the module Random Access Memory (RAM) is lost. Configuration
information, however, is not lost. Table 3-10 lists the information preserved
and lost upon a warm start of the module.
Table 3-10. RMON MultiProbe Module Information Preserved
and Lost on Warm Start
Information Preserved Information Lost
All installed filter and channel tables Captured Packets
Buffer Control Table Counted Packets
History Control Table Historical Ethernet Statistics
Alarm Table Current Ethernet Statistics
Event Table Matrix Tables
Community Access Table Entries Host Top N Tables
Client Table Entries Host Tables
Module Configuration Entries
(IP Address, Subnet Mask)
Logs
TFTP Server Address
Download Filename
Time Zone
Serial Port Configuration
Information
Serial Connection Table
Trap Destination Table