3Com RMON-EMP-3 Network Card User Manual


 
3 - 42 Ethernet RMON MultiProbe Module Installation and Operation Guide
Cold-Starting the RMON MultiProbe Module
When you re-initialize the RMON MultiProbe Module by initiating a cold
start (for example, by selecting option 4 from the Main Configuration
menu), all network management information is lost, with the exception of
the following interface and module configuration information:
IP address (for each interface)
Subnet mask (for each interface)
Default gateway (for the module)
Table 3-11 lists the information that is preserved and lost upon a cold start
of the module.
Table 3-11. RMON MultiProbe Module Information Preserved
and Lost on Cold Start
Information Preserved Information Lost
Module Configuration Information
(IP Address, Subnet Mask,
Default Gateway)
Community Access Table Entries
(reverts to defaults)
TFTP Server Address Client Table Entries
(reverts to defaults)
Download Filename Packet Capture Filters
Time Zone Captured Packets
Serial Port Configuration
Information
Counted Packets
Historical Ethernet Statistics
Current Ethernet Statistics
Host Tables
Matrix Tables