74 APPENDIX E: REDUNDANT POWER SUPPLY SAFETY INFORMATION
WARNING: Ensure that the circuit breaker in the RPS is in the open (off)
position when connecting the RPS cable and connector to the Switch.
WARNING: Do not use a standard 'positive-earthed' -48V redundant
power system suitable for use with telecommunications equipment with
the 3Com Power-over-Ethernet (PoE) network switches. In order to meet
the IEEE 802.3af (PoE) specification, the -48V output must be isolated
from earth (ground) and meet the isolation requirements in that
specification.
L’information de Sécurité Importante
AVERTISSEMENT: Ce périphérique comporte plusieurs entrées
d'alimentation. Déconnectez toutes les entrées d'alimentation afin de le
mettre hors tension.
AVERTISSEMENT: L'installation du RPS (Redundant Power Supply) ne
doit être confiée qu'à un personnel formé et qualifié.
AVERTISSEMENT: Ces instructions doivent être lues conjointement avec
les instructions d'installation et les consignes de sécurité qui
accompagnent le RPS.
AVERTISSEMENT: Lorsqu'un commutateur Switch 4210 est alimenté par
un module RPS, l'unité doit être mise à la terre. Pour cela, branchez le
cordon d'alimentation à l'unité ou branchez la borne de mise à la terre
située à l'arrière de l'unité à une prise de terre fiable, ou procédez aux
deux raccordements. Assurez-vous que l'unité est mise à la terre avant de
raccorder l'alimentation CC du RPS.
AVERTISSEMENT: Le RPS doit être approuvé en tant que sortie SELV non
reliée à la terre, conformément à la norme IEC 60950-1/UL 60950-1/EN
60950-1.
AVERTISSEMENT: Ces instructions doivent être lues conjointement avec
les caractéristiques de l'alimentation CC du Switch 4210 fournies en
annexe C, Spécifications techniques.
AVERTISSEMENT: Vous devez respecter les recommandations du
fabricant lors du branchement du câble au module RPS.