Setting Up and Testing the Desktop Unit
2-2 Campus-RS Desktop Unit User Manual
Install the NID on the HDSL line between the HDSL jack and the Telephone
Company (Telco) demarcation point.
ADC also suggests providing power line protection for critical circuits in high
lightning areas. Use conditioned AC voltage, furnished through an
Uninterruptible Power Supply (UPS), that is bonded to a good facilities
ground. This provides additional protection against voltage transients
entering through the power lines.
PROTECTING MULTIPLE CAMPUS-RS DESKTOP
U
NITS FROM OVERHEATING
If you plan to operate multiple Campus-RS Desktop Units in a confined area,
take the following precautions in order to avoid overheating the units:
• Do not stack Desktop Units on top of each other
• Do not place any object on top of the Desktop Units
• Do not obstruct the cooling vents
For maximum thermal efficiency, ADC recommends using the CEN-604
shelf (part number 150-1212-01).
NID
HDSL line
Campus-RS Unit
HDSL line port
Telco demarcation point
HDSL
jack