ADTRAN TDU 120e Network Card User Manual


 
Chapter 8. Remote/Management Menus
61202156L2-1A TDU 120e User Manual 8-3
The following chart describes each command of the Unit
Access Table.
Table 8-1. Unit Access Table Commands
Command What it does...
Add New Unit
Adds a new device to the table.
You must enter a device Unit ID, passcode, Unit type, and polled
flag. Unit type can be:
Standard (which supports any TSU/TDU Multiplexer and the ISU
512), or TSU Standalone (a single port TSU with no option card slot).
A passcode of 0 to 9999 for each device or
DEFAULT
may be
selected, which results in the default passcode being used (defined
as 0022 in Figure 8-1 on page 8-2).
Traps are normally sent from the unit in alarm to the TDU 120e. For
units in the Unit Access Table that are not chained directly to the
TDU 120e but are managed over Inband or the FDL, traps are not
automatically forwarded. Polling must be enabled on the TDU 120e
for these units in order to receive Traps on the NMS. The TDU 120e
can be configured to poll selected units for traps by enabling the
polled option when adding or modifying a unit entry.
Modify Unit
Allows unit ID, passcode, device type, and polled flag to be changed
for an existing entry in the table.
Delete Unit
Deletes an entry in the table.
Default Unit
Passcode
Sets the default passcode for all devices in the table that have
passcodes set to
DEFAULT
, or for any unit not listed in the table.
OK
Returns to the
C
ONFIGURE
A
GENT
menu.