ADTRAN TDU 120e Network Card User Manual


 
Appendix A. Understanding SNMP
A-6 TDU 120e User Manual 61202156L2-1
SNMP MIB Browser Configuration
The following steps are required to configure Network
Manager MIB variable access through the TDU 120e:
Step Action
1
Load the desired product MIBs on the network
management station.
Example:
If the administrator is managing TDU 120e and ISU 512
devices, load TDU 120e.MIB, ISU512.MIB, and
RFC1406.MIB.
2
Create device entries in the NMS database for all units
that are to be managed through the TDU 120e.
The host unit should be configured as the Proxy agent for
the external units. The IP address or host name used for
the proxy designation is that of the TDU 120e.
3
Set community names in the device’s entries for external
units to the TDU 120e community name with the device
Unit ID appended.
See TDU 120e SNMP ACCESS on page A-4 for more
information.
4
Set the device timeout for all device entries in the NMS
device database to five seconds, including the host unit.