ADTRAN TDU 120e Network Card User Manual


 
Chapter 5. Configuration Menu
61202156L2-1 TDU 120e User Manual 5-25
Dial Backup Config
Under DBU C
ONFIG
, the menu items are:
Backup Mode
In a backup condition, both ends of the circuit must
detect backup conditions before backup is activated.
One DBU is set to O
RIGINATE
and the other to
A
NSWER
. Upon a network failure, only the Originate
DBU initiates backup by dialing the ANSWER
END
.
Once called, the ANSWER
DBU goes into backup
mode only if a backup condition is detected. This is
ideal for controlling where calls originate.
Choices: D
ISABLE
, O
RIGINATE
, A
NSWER
Backup On
Selects the conditions that cause the Nx/DBU to ini-
tiate Backup.
NET FAIL
Backup occurs on R
ED
A
LARM
, Y
ELLOW
A
LARM
, B
LUE
A
LARM
and LOS.
Table 5-1. Normal Mode of Operation
RTS V.54
Loopback
511 TST
ON
Self Test
Active
Netwk Test
Active
No DS0
Mapped
Network
Alarm
CTS Follows OFF OFF OFF OFF OFF
DCD OFF OFF OFF
DSR OFF OFF OFF OFF
Where “—” = don’t care
Force On = On under all conditions
This table indicates conditions which cause the
P
ORT
C
ONTROL
S
IGNALS
to be deactivated.