Agilent Technologies E1439 Network Card User Manual


 
106
Agilent E1439 Programmer's Reference
Functions listed alphabetically
age1439_fiber_clear
This function clears all data from the fiber interface FIFO buffers.
VXIplug&play Syntax
#include "age1439".h
ViStatus age1439_fiber_clear(ViSession id);
Description
age1439_fiber_clear clears all data from the fiber interface FIFO buffers, and resets other
internal transient states such as, "reset to beginning of epoch"and"return to copy phase of
append".
Parameter
id is the VXI instrument session pointer returned by the age1439_init function.
Return Value
AGE1439_SUCCESS indicates that a function was successful.
Values other than AGE1439_SUCCESS indicate an error condition or other important status
condition. To determine the error message, pass the return value to “age1439_error_message” on
page 102.
See Also
“age1439_init” on page 132, “age1439_status_get” on page 176