Airlink X EV-DO Modem User Manual


 
Raven X EV-DO for Verizon - User Guide, version 2.34 136
Frequently Asked Questions and Technical Support
Using ALEOS
Using Direct Commands to the internal hardware (use only if the above is
unsuccessful)
TABLE 1. Provisioning
Command Description
1
AT*TELNETTIMEOUT=20
(this command and the next is only needed for an
Ethernet connection)
Set telnet timeout in modem to 20 minutes.
2
AT& W
Save the telnet setting.
3
ATI 3
Verify ALEOS has established communica-
tion to the internal hardware.
4
If you have the same number for the MIN and MDN:
AT*PROVISION=MSL,MDN[,SID,NID]
If you have the different numbers for the MIN and
MDN:
AT*PROVISION2=MSL,MDN,MIN[,SID,NID]
Enter the activation command appropriate
for your type of account. The SID and NID
are optional and only required if your
account type uses them.
TABLE 2. Prepare for Provisioning
Command Description
1
AT*TELNETTIMEOUT=20
Set telnet timeout in modem to 20 minutes.
2
AT& W
Save the telnet setting.
3
ATI3
Verify ALEOS has established communica-
tion to the internal hardware.
4
AT\APASSTHRU
Put modem into passthru mode to by-pass
ALEOS.
This will allow direct communication with
the wireless module for programming.
Entering passthru will take 10-15 seconds
and will return an ‘OK’ when it is com
-
plete.
**Passthru mode causes first 3 LEDs to
blink simultaneously.
5
ATI0
(the letter “I” and the number “0”)
This will verify you are in Passthru mode.