AMCC PN 720-0104-00 Computer Drive User Manual


 
3ware Disk Manager (3DM 2)
46 3ware 9000 Series Serial ATA RAID Controller User Guide
The Summary page appears after you first logon to 3DM, and when you click
the Summary link in the menu bar.
The Summary page provides basic information about each 3ware RAID
controller in your system. To see details about the units in a controller, click
the link in the ID column.
ID. The ID that the operating system assigns to the controller.
Note: The controller ID you see in 3DM 2 may not match the
number that you see for the same controller in 3DM version 1.x.
Model. The model name of the controller. (The model number is also printed
on a sticker on the outside bracket of the controller.)
Serial #. The serial number of the controller. (The serial number is also
printed on a sticker on the outside bracket of the controller.)
Firmware. The firmware version running on the controller.
Driver. The driver version being used to interact with the controller.
Status. The overall status of the controller. Possible statuses include OK,
Warning, Error, and No Units. Warning indicates that a background task is
currently being performed (rebuilding, verifying, or initializing). Error
indicates that a unit is degraded or inoperable. If both Error and Warning
conditions exist, the status will appear as Error.