Asante Technologies IC36240 Power Supply User Manual


 
Chapter 5: Managing the System and Configuration Files
This chapter explains how to manage the system information, as well as how to manage the configuration files for the
IntraCore IC36240.
5.1 Managing the System
This section discusses the following tasks needed to manage the system information of the IntraCore IC36240:
Setting the System Clock
Configuring the Host name
Changing the Password
Testing Connections with Ping Commands
Enabling Syslog
Displaying the Operating Configuration
5.1.1 Setting the System Clock
The IntraCore IC36240 has two ways to set clock.
To manually set the system clock, complete the following commands in privileged mode. Use a space and a question
mark (?) to display the clock set options. Restart the system after configuring the clock by typing reload at the
Switch# prompt and pressing Enter.
Switch# clock ?
set Set the time and date
Switch# clock set ?
HH:MM:SS Current Time
Switch# clock set 09:29:30 ?
<1-31> Day of the month
Switch# clock set 09:29:30 28?
<1-31> Day of the month
Switch# clock set 09:29:30 28 ?
MONTH Month of the year (for example: June or July)
Switch# clock set 09:29:30 28 January ?
<1970-2069> Year
Switch# clock set 09:29:30 28 January 2005
Switch# reload <cr>
To use Simple Network Time Protocol, enter the commands below:
Switch# configure
Switch# (config) Clock timezone pacific hour 8 minute 0 after-utc
Switch# (config sntp server A.B.C.D
A.B.C.D is the IP address of a time server.
37 Asante IntraCore IC36240 User’s Manual