IntraCore IC3624PWR Layer 2 PoE Switch with Dual Gigabit
3.3 Site Requirements
Consider the following site requirements for proper installation.
3.3.1 Environmental Requirements
Choose a clean, dry, dust-free area location. Avoid direct sunlight, heat sources, or areas with high levels of
electromagnetic interference. Failure to observe these limits may cause damage to the switch and may void the
warranty.
3.3.2 Power
Make sure the power source adheres to the following guidelines:
Outlet: Properly grounded, located near the switch, and easily accessible
Power:
Auto Switching 100-240 VAC, 50/60 Hz, maximum 225 watts
Frequency range:
50/60 Hz
3.3.3 Cooling and Airflow
The IC3624PWR PoE switch use internal fans for air-cooling. Do not restrict airflow by covering or obstructing air
vents on the sides of the switch.
Operating Temperature: 32° to 104°F (0° to 40°C)
Relative Humidity: 10% to 90% non-condensing
3.3.4 Rack Mounting
Before mounting the switch in a rack follow these general precautions:
Size: 17.3 x 9.9 x 1.7 in (440 x 253 x 43 mm)
Weight: 9.5 lb (4.3 kg)
Temperature: The temperature within a rack assembly may be higher than the ambient room temperature check that
the rack-environment temperature is within the specified operating temperature range remains below 104°F (40°C).
Clearance:
Clear all obstructions, such as other equipment or cables, block airflow to or from the vents of the switch.
Be sure there is adequate clearance for servicing the switch.
Mechanical Loading: Do not place any equipment on top of a rack-mounted unit.
Circuit Overloading:
Be sure that the supply circuit to the rack assembly is not overloaded.
Grounding:
Rack-mounted equipment should be properly grounded. Particular attention should be given to supply
connections other than direct connections to the mains.