Asante Technologies IC3624PWR Switch User Manual


 
82
IntraCore IC3624PWR Layer 2 PoE Switch with Dual Gigabit
Note: The “+” and “-” signs represent the polarity of the wires that make up each wire pair.
C.1.2 Straight-Through Wiring
If the twisted-pair cable is to join two ports and only one of the ports has an internal crossover (MDI-X), the two pairs
of wires must be straight-through. (When auto-negotiation is enabled for any RJ-45 port on this switch, you can use
either straight-through or crossover cable to connect to any device type.)
White/Orange Stripe
Orange
White/Green Stripe
Green
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
EIA/TIA 568B RJ-45 Wiring Standard
10/100BASE-TX Straight-through Cable
End A
End B
C.1.3 Crossover Wiring
If the twisted-pair cable is to join two ports and both ports have the same indicator (MDI or MDI-X) a crossover must
be implemented in the wiring. (When auto-negotiation is enabled for any RJ-45 port on this switch, you can use either
the straight-through or the crossover cable to connect to any device type.)
White/Orange Stripe
Orange
White/Green Stripe
Green
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
EIA/TIA 568B RJ-45 Wiring Standard
10/100BASE-TX Crossover Cable
End A
End B
C.2 Pin Assignments for 1000BaseT Pin
All 1000BaseT ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network
connections to PCs or servers, or to other switches or hubs.