ATTO Technology 5300 Computer Hardware User Manual


 
xi
ATTO Technology Inc. FastStream VT 5300 Installation and Operation Manual
DefaultInterleave
DefaultInterleave assigns or retrieves the system-default
interleave size for new RAID Groups. If an interleave size
is not explicitly specified when a RAID Group is created,
then the DefaultInterleave value is used instead.
Default: 128
set DefaultInterleave [16 | 32 | 64 | 128 | 256 ]
get DefaultInterleave
DHCPFixedDelay
Selects/displays the delay, in seconds, between DHCP
client request intervals, from between 0 seconds to 255
seconds. 0 time is typical.
Default: 0 (no delay)
set DHCPFixedDelay [ 0 - 255 ]
get DHCPFixedDelay
DisplayEventLog
Displays the most recent page of event log entries. Typing
a
+
,
-
or
=
causes the next, previous or same page of event
log entries to be displayed. No events are recorded until
the command has been completed. Type
q
to disable the
command, begin new log entries, and return to CLI.
DisplayEventLog < + | - | = | q >
DisplayEventLogFilter
Filters the display of data for specified subsystems and
levels during
DisplayEventLog
mode. Valid event log
subsystem entries are platform-dependent.
Subsystem Levels
ECC INFO
ENET WARN
GEN CRIT
HTTP FAIL
NVRAM ALL
PERF
SCSI
NDMP
FC
ALL
Default: all all
set DisplayEventLogFilter [subsystem | all] [level | all]
get DisplayEventLogFilter [subsystem | all] [level | all]
DriveTest
Immediate command which starts or stops a drive test
with the previously specified configuration and drive list.
Drives which are in-use by the test are not available for
RAID configuration or RAID operations. Only one test
can be run at a time.
DriveTest [Begin | Cancel]
DriveTestConfig
Configures the next drive test to perform one of the
following operations: initialize (destructive write-only),
read (non-destructive read-only), verify (destructive
verify), or init-verify (destructive write-read-verify).The
test is not started until the
DriveTest Begin
command is
given.
Default: not initiated
set DriveTestConfig [init | read | verify | init-verify]
get DriveTestConfig
DriveTestList
Specifies drives to be run in the next drive test including
drives which are not part of a RAID group and not Hot
Spares. The
all
parameter automatically chooses eligible
drives. The test is not started until the
DriveTest Begin
command is given.
set DriveTestList [drive [BlockDevID] | all]
get DriveTestList
DriveTestStatus
Displays the status of the currently running drive test but
does not display performance metrics. If a block device
ID is not running or cannot be found, its state is
idle
and
percent complete is
0.
get DriveTestStatus <drive [BlockDevID]>
DumpConfig
Displays a unit’s configuration.
DumpConfig
DumpEventLog
Dumps the contents of the entire event log to the current
CLI session without impact on the log itself (the log is not
cleared). No events are recorded until the command has
been completed.
DumpEventLog
EmailFromAddress
Configures the E-mail address that the FastStream uses
to talk to the E-mail server. Full E-mail address is a fully
qualified Internet E-mail address, not more than 128
characters.
set EmailFromAddress [full email address]
get EmailFromAddress
EmailNotify
Regulates E-mail notification.
Default: disabled.
set EmailNotify [enabled | disabled]
Requires a SaveConfiguration command
get EmailNotify