ATTO Technology 5300 Computer Hardware User Manual


 
xii
Appendix
EmailNotifyAddress
Configures notification addresses using an index (a
number between 1 and 5, inclusive), the full E-mail
address of the recipient, a fully qualified Internet E-mail
address not more than 128 characters long, and a level.
Levels are
.....
None: no E-mails sent.
.....
Critical: critical event notification.
.....
Warning: warnings and critical event notification.
.....
All: all warnings, critical events
set EmailNotifyAddress [index] [full email address]
[warning level]
get EMailNotifyAddress
EmailPassword
Configures the password used to authenticate the login to
the SMTP email server. The password must not be more
than 64 characters. A password is not required if the
email server does not require authentication.
set EmailPassword
EmailServerAddress
Configures the address of the server that the FastStream
should contact in order to send E-mails.
Default: 0.0.0.0
set EmailServerAddress [IP address]
get EmailServerAddress
EmailUsername
Configures the username used to authenticate the login to
the SMTP email server. The username must not be more
than 128 characters. A username is not required if the
email server does not require authentication.
set EmailUsername [Username]
get EmailUsername
EthernetMDIX
Specifies the Ethernet twisted-pair connection type.
The
MDI
setting connects the unit's Ethernet port to an
Ethernet hub or switch port with a standard Ethernet
patch cable (or to a PCI card with a cross-over cable).
The
MDIX
setting connects the unit's Ethernet port to an
Ethernet PCI card with a standard Ethernet patch cable
(or to a hub or switch with a cross-over cable).
The
Auto
setting attempts to automatically determine the
correct setting.
Default: MDI
set EthernetMDIX [mp1] [MDI | MDIX | auto]
get EthernetMDIX [mp1]
EthernetSpeed
Sets/displays the current speed of the Ethernet
connection. Choices are
10, 100
, and
Auto
.
Default: auto
set EthernetSpeed [mp1] [ 10 | 100 | Auto ]
Requires a SaveConfiguration command
get EthernetSpeed [mp1]
EventLog
When enabled, records various system errors to the event
log.
Default: enabled
set EventLog [enabled | disabled]
get EventLog
EventLogFilter
Filters data from specific unit subsystems and levels when
event logging is enabled. The specific entries supported
are platform-dependent.
Subsystem Levels
ECC INFO
ENET WARN
GEN CRIT
HTTP FAIL
NVRAM ALL
PERF
SCSI
NDMP
FC
ALL
set EventLogFilter [subsys | all] [event level | all] [all |
none]
get EventLogFilter [subsystem] [level]
Exit
Exits the current Ethernet telnet CLI session; it has no
effect if used during a serial or in-band CLI session.
Exit
FCConnMode
Controls/reports the connection mode the FastStream
uses when communication across a FC network, either to
an arbitrated loop (FC-AL) when you select
loop
mode,
or point-to-point when you choose
ptp
. If you choose
loop-ptp
or
ptp-loop
, the FastStream tries to use the
first parameter first.
Default: loop
set FCConnMode [fp] [loop | ptp | loop-ptp | ptp-loop]
Requires a SaveConfiguration command
get FCConnMode [fp]