THE BADGER
®
-RADIX
®
User Guide
February 2007
Page 68 of 73
Badger
®
ORION
®
Quick Reads
Badger ORION Quick Reads offer you great flexibility. Because the Badger ORION
Receiver will forward all Badger ORION readings it receives, you can view up to 50
readings received or you can request to view readings from a specific Badger ORION
transmitter. Press the “O” key to display the Orion Quick Read screen. It looks like this.
The ORION Quick Read screen can also be reached by using the “Q” Hot Key.
If you wish to look for a reading from a specific Badger ORION receiver, touch the “O”
key to place a check mark in the Select One Serial Number field. Next touch the “S” key
to enter the Serial Number. The numeric entry screen will come up to allow you to enter
the serial number of the transmitter you want to read. Enter the serial number and press
the “Enter” key. The Badger-Radix will display the Quick Read screen with your chosen
serial number, and will begin listening or that transmitter. When a reading is received,
the Badger-Radix will sound the reading tone and display the reading. Every time a
reading is received from that transmitter, the screen will be updated and the tone will
sound. Here are tree examples of Quick Read displays, one with a Badger ADE
®
and no
tamper reported, another with a Badger RTR
®
but a tamper condition reported, and a
quick read of a Badger ORION Gas transmitter.