Barco R9001070 Projector User Manual


 
Random Access Adjustment Mode
Random Access Adjustment Mode
5975696 BARCODATA 2100 14079810-8
10-8
5975696 BARCODATA 2100 140798
Select "Vertical" by pushing the control disk key up or down and
press ENTER. The full image is displayed.
The "Vertical Total lines" are already filled when an active file is
selected to be edited.
The "Active lines" : number of horizontal lines determining the height
of the projected image. This value is normally given in the specification
of the source. If not, adjust until full image height is displayed (no
missing lines)
Vertical shift : shift the image up and down (push control disk up or
down) on the screen until the correct image position is obtained.
When changing the vertical shift setting in the 'Edit' menu, the
vertical shift and vertical size settings in 'geometry' are reseted.
Interlaced [On] or [Off] : this selection is automatically filled when
active file has to be edited. If the image is wrong due to
mismeasurement, use the ENTER key to toggle between [On] and
[Off]. (for interlaced images, 1 frame contains 2 fields).
Read AMDS
AMDS = automatic mode detection & synchronisation
During the installation of a file with LOAD, the system automatically
measured the horizontal period, the total vertical lines and the
interlaced mode.
When selecting Read AMDS, the system remeasures the above
indicated items.
864
Select "Vertical" by pushing the control disk key up or down and
press ENTER. The full image is displayed.
The "Vertical Total lines" are already filled when an active file is
selected to be edited.
The "Active lines" : number of horizontal lines determining the height
of the projected image. This value is normally given in the specification
of the source. If not, adjust until full image height is displayed (no
missing lines)
Vertical shift : shift the image up and down (push control disk up or
down) on the screen until the correct image position is obtained.
When changing the vertical shift setting in the 'Edit' menu, the
vertical shift and vertical size settings in 'geometry' are reseted.
Interlaced [On] or [Off] : this selection is automatically filled when
active file has to be edited. If the image is wrong due to
mismeasurement, use the ENTER key to toggle between [On] and
[Off]. (for interlaced images, 1 frame contains 2 fields).
Read AMDS
AMDS = automatic mode detection & synchronisation
During the installation of a file with LOAD, the system automatically
measured the horizontal period, the total vertical lines and the
interlaced mode.
When selecting Read AMDS, the system remeasures the above
indicated items.