Bay Technical Associates U140E116-02 Network Card User Manual


 
12
Unit 2 Module 1
REV. 4.XX Copyright (c) 1995-1997
Bay Technical Associates
To login, enter password
Login: BTA (default)
You will be prompted to type in the desired password followed by
<ENTER> when a connection to the V93A modem is first made. You are
given three tries to type in the correct password before the modem hangs up.
Type the appropriate password (Default is BTA). The V93A will respond
with:
Login successful
Port Select Code: $BT
Attnetion Character: ;
Among the functions you can perform are data commands/port selection and
configuration. Configuration commands are used to program the features of
the various I/O modules and the data commands are typically used to request
stored data received from an I/O module. Data commands are also used to
instruct certain I/O modules to perform a specific task (e.g., energize or de-
energize a relay).
The configuration menu is invoked by selecting configure(C) from the port
selection menu. The supported configuration and data commands for a
specific I/O module are described in the documentation for that module.
.2 PORT SELECTION MENU
To activate the port selection menu, type 5 or more ;;;;; (default) in a row
and a menu similar to the following will appear.
. M-Series V93A DAC Host
Unit 1 Module 2
REV. 4.00 Copyright(c) 1995-1997
Bay Technical Associates
Device A (2,1)............1