Bay Technical Associates U140E116-02 Network Card User Manual


 
23
This time-out can be programmed from 5 to 255 minutes, or 0 (=disable). The
timer is started when the modem goes off-hook (DCD goes high), and the
modem will return to “on hook” after the time-out has expired. The factory
default is 0 (disabled).
.9 EXIT
By responding with "X" (Exit), you will exit configuration mode. At this point,
the V93A is awaiting a command from the host device
(i.e., Attention Character sent five times).
.10 ECHO MODE
The V93A can be placed into echo mode by sending seven semicolons (;) in
succession. While in echo mode, the V93A will echo all characters received
by the connected device back to that device. Echo mode is terminated by
placing an I/O module into command mode ($BTm<cr> where m is the
desired module number. Echo Mode would be used only when the ASCII
string method of port selection is used. If the Menu Mode(Attention character
method) of port selection is used the Echo Mode is not required.
.11 RING DETECT RESET
The V93A has a Ring Detect Reset feature that will automatically cycle power
on the M Series unit if an incoming call is detected and not answered within
seventy seconds. The Ring Detect Reset feature is enabled by connecting a
straight 2-wire or 4-wire cable between the auxiliary 4-pin modular connector
on the V93A and the DIAL service modem port on the M Series chassis.
.12 MODEM LED INDICATORS