If you type "Y", the new configuration for the selected port is stored
permanently in non-volatile memory until. If you type “N” the V93A will
return to the main configuration menu.
NOTE: If you are configuring the V93A from the EIA-232 port, the V93A
will respond with:
Change Device to NEW Configuration
Before Answering This Request.
CAUTION: This message reminds you to change the serial port
configuration of the host device now. If they do not match, the V93A will be
unable to interpret the next command. If this happens, cycle power on the M-
Series DAC and reconfigure the unit.
.3 PORT DEVICE NAME
By responding with "3" (Port Device Name), you can change the Port Device
Name. The V93A module will respond with a menu similar to the following:
Module 1 Device Name :
+----+-----------+-----+-----+----+------+-----+---+
|Port| Device |Baud |Word |Stop|Parity|Xon/Xoff|
| | Name |Rate |Size |Bits| |Xmit|Recv|
+----+-----------+-----+-----+----+------+-----+---+
| 1 |Device D |9600 | 8 | 1 | None |Off |Off|
+----+-----------+-----+-----+----+------+-----+---+
Enter Port Device Name (Max. 16 characters):
or ENTER for no change ...........:
Enter the desired Port Device Name up to 16 characters. For example, if you
type "PORT 4" followed by <ENTER>, the module will respond with:
Module 1 Device Name :
+----+-----------+-----+-----+----+------+-----+---+
|Port| Device |Baud |Word |Stop|Parity|Xon/Xoff|
| | Name |Rate |Size |Bits| |Xmit|Recv|
+----+-----------+-----+-----+----+------+-----+---+
| 1 |Port 4 |9600 | 8 | 1 | None |Off |Off|
+----+-----------+-----+-----+----+------+-----+---+