3.6.4 Menu 4: Clear EEPROM
This menu selection is available if it is believed that the data in the D8125INV is corrupted and you wish to clear the
information and reprogram it. To clear the EEPROM, follow the steps shown below.
1.
To access this menu selection, press 4 from the main menu. The
keypad will display:
followed by:………………………………………………………
and then: ………………………………………………………
2.
Push the [ENT] key. Since clearing the EEPROM will delete the
entire point database and default the D8125INV to the default
settings, another confirmation is required to proceed.
3.
If you wish to exit from this menu, press the [ESC] key. Otherwise, push the [ENT] key one more
time to confirm that you wish to have the EEPROM erased.
Note: The System ID is maintained even after EEPROM is cleared, however, everything else is brought back to factory
default values.
3.6.5 Menu 5: Set RF System Supervision Interval
The RF System Supervision Interval determines how long the D8125INV will wait to hear at least one check-in
transmission (or any transmission) from a transmitter before sending a Missing condition to the Control Panel. The
interval value that is chosen applies to all transmitters system wide. To set the RF System Supervision Interval, follow the
steps shown below.
1.
To access this menu selection, press 5 from the main menu. The
keypad will then display the following menus:
<value> = None, 4 hr., 12 hr., or 24 hr.
Note: All transmitters follow the programmed supervision
interval except the FA113 Keyfob and fire points.
Note: The supervision interval begins when the D8125INV
powers up. If removing a battery in a transmitter to test
this feature, the supervision interval starts before the
transmitter is programmed, taking until the end of the
next supervision window to go into trouble.